ASTM D4332 PDF

This standard is issued under the fixed designation D ; the number 1 This practice is under the jurisdiction of ASTM Committee D10 on. Keystone Compliance is a full-service ASTM D test lab. Our ASTM D package testing knowledge and experience expedite the test process and assists . ASTM D Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing.

Author: Shalkree Samugami
Country: Fiji
Language: English (Spanish)
Genre: Technology
Published (Last): 20 February 2017
Pages: 180
PDF File Size: 13.16 Mb
ePub File Size: 11.22 Mb
ISBN: 478-8-84603-288-8
Downloads: 56791
Price: Free* [*Free Regsitration Required]
Uploader: Vudolmaran

ASTM-D4332

These special conditions do not necessarily duplicate actual? Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. ASTM D e1.

When this is not possible, the test shall be performed as quickly as possible after the specimen is removed from the conditioning atmosphere. A psychrometer may be used either for direct measurement of relative humidity or for checking the hygrometer see Test Method E Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

The container, package, or packaging component shall be supported in a manner such that all surfaces have free access to the conditioning atmosphere. Historical Version s – view previous versions of standard. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. Current edition approved April 10, Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Headquarters.

  JURNALUL UNUI ADOLESCENT TIMID PDF

A number in parentheses indicates the year of last reapproval.

Climatic Conditioning Testing | Anecto

The dry-bulb thermometer of the psychrometer may be used either for atsm measurement or for checking the temperature-indicating device. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Work Item s – proposed revisions of this standard. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every?

This standard is commonly used for conditioning when conducting transit simulation tests. Last previous edition D — X4332 1—Average values must fall within these limits.

D Terminology of Packaging and Distribution Environments. A superscript epsilon e indicates an editorial change since the last revision or reapproval.

ASTM-D – Medical Package Testing

Originally published as D — It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Heavier packages may be placed on a pallet or other device that should allow for as much exposure of the bottom surface to the conditioning atmosphere as is possible, so long as the device does not cause a permanent change in the box or affect the? It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  JBL 4425 PDF

See Test Method E for a detailed description of methods. These special conditions do not necessarily duplicate actual field conditions, but tend to simulate them and have effects on packages and materials which may be related to their field performance.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. Precision and Bias 9. NOTE 4—In the absence of a speci? Therefore, the package should be placed and kept in a speci? Link to Active This link will always route to the current Active version of the standard. Therefore, the package should be placed and kept in a specified atmosphere for a length of time such that subsequent measurements of physical properties will be meaningful and reproducible.

If no time period is speci? Tolerances at the controller usually must be smaller than those at the specimen. Conditioning for Testing5 2. Here too, the package shall be tested as quickly as possible after removal from the conditioning atmosphere. The temperature and relative humidity indicated at the control point, may not be representative of conditions elsewhere in the conditioned space due to local effects or de?